The Hanger Array command assists populating hangers for duct and pipe runs. It works on both Standard Revit Systems elements and Fabrication items. 


Prerequisites:

  • At least one compatible hanger family must already be loaded into the project. 
    • See Hanger Families for more information on loading the two simple hangers that BIMrx supplies.
    • Hanger families used in the Hanger Array command will only work with standard Revit Systems elements of duct and pipe.


In Revit:

  • Navigate to the BIMrx tab >> BIMrx Fabrication panel >> Hanger Array command. 


  • This will open up the Hanger Distribution Settings dialog:


The Hanger Distribution Settings dialog generally consists of two regions. On the left side is the Define Settings region, where you can create, delete, duplicate hanger distribution settings, appoint a default distribution setting, and associate the hanger distribution setting to a Service:


On the right side is the Adjust Settings region, where you can rename the selected setting, and adjust current setting in detail:


Hanger Families

Creating Hanger Distribution Settings

Adjusting Hanger Distribution Settings

Associate Hanger Distribution Setting To Service

Selecting Runs

Selecting Hanger Families/Items